Compact

Compact pellet boiler for confined spaces (under the staircase, storage room, small utility compartments, etc.) with high performance levels and extensive operating control. The hydraulic part can be completed with 4 different kits depending on the system’s needs. Wide range of pellet loading and storage systems (from 200kg to 1900kg). You can check the temperature of the puffer tank and/or domestic hot water through the boiler’s panel.

WIDE OPERATING RANGE FROM 13 TO 40,5 KW

LARGE PELLET TANK PROVIDED (C45/C35: 146 l, C18/C24: 100 l, C14: 35 l)

Diagram of details

Programmable electronics that manages the boiler functions (including chimney sweep and summer/winter functions).
Cast iron grate unit for long-lasting durability.
The hydraulic part can be completed with 4 different kits depending on the system’s needs.
Large ash tray for a weekly clean.
Combustion air that can be ducted from outside for maximum efficiency of the system, ideal for homes with low energy consumption levels (Compact 14/18/24/35).
COMPACT 14:
Filling tank provided with a capacity of approximately 35 litres (about 24 kg).

COMPACT 18-24:
Filling tank provided with a capacity of approximately 100 litres (about 70 kg).

COMPACT 35-45:
Filling tank provided with a capacity of approximately 146 litres (about 100 kg).

Technical data

Fuel type pellet
Class compliant with EN303-5 5
Nominal thermal power to firebox 14.40 kW
Max nominal output power 13.00 kW
Minimum output power 3.70 kW
Thermal power with fluid 13,00 kW
Nominal performance 90.30%
Hopper capability 35.00 lt
Hourly consumption at min 0.85 kg/h
Hourly consumption at max 3.00 kg/h
Runtime at min 27.00 h
Runtime at max 8.00 h
Heatable volume 319/35
Diameter of smoke outlet pipe 10 cm
Weight 190 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 108 ºC
Massive smoke capacity 9.70 g/s
Boiler water capacity 20 l

 

Compact Technical designs
Fuel type pellet
Class compliant with EN303-5 5
Nominal thermal power to firebox 18.10 kW
Max nominal output power 17.00 kW
Minimum output power 3.80 kW
Thermal power with fluid 17,00 kW
Nominal performance 93.80%
Hopper capability 100.00 lt
Hourly consumption at min 1.00 kg/h
Hourly consumption at max 3.60 kg/h
Runtime at min 68.00 h
Runtime at max 19.00 h
Heatable volume 418/35
Diameter of smoke outlet pipe 10 cm
Weight 200 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 110 ºC
Massive smoke capacity 12,7 g/s
Boiler water capacity 25 l
DHW flow rate 8.10 l/min

 

Compact Technical designs
Fuel type pellet
Class compliant with EN303-5 5
Nominal thermal power to firebox 24.50 kW
Max nominal output power 22.10 kW
Minimum output power 3.80 kW
Thermal power with fluid 22,10 kW
Nominal performance 90.20%
Hopper capability 100.00 lt
Hourly consumption at min 1.00 kg/h
Hourly consumption at max 4.80 kg/h
Runtime at min 68.00 h
Runtime at max 15.00 h
Heatable volume 543/35
Diameter of smoke outlet pipe 10 cm
Weight 200 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 150 ºC
Massive smoke capacity 17,5 g/s
Boiler water capacity 25 l
DHW flow rate 10.50 l/min

 

Compact Technical designs
Fuel type pellet
Class compliant with EN303-5 5
Nominal thermal power to firebox 34.50 kW
Max nominal output power 32.00 kW
Minimum output power 8.10 kW
Thermal power with fluid 32,00 kW
Nominal performance 92.80%
Hopper capability 146.00 lt
Hourly consumption at min 1.30 kg/h
Hourly consumption at max 6.70 kg/h
Runtime at min 80.00 h
Runtime at max 16.00 h
Heatable volume 786/35
Diameter of smoke outlet pipe 10 cm
Weight 300 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 140 ºC
Massive smoke capacity 21,5 g/s
Boiler water capacity 30 l
DHW flow rate 15.30 l/min

 

Compact Technical designs
Fuel type pellet
Class compliant with EN303-5 5
Nominal thermal power to firebox 45.00 kW
Max nominal output power 32.00 kW
Minimum output power 12.00 kW
Thermal power with fluid 40,50 kW
Nominal performance 90.00%
Hopper capability 150.00 lt
Hourly consumption at min 1.30 kg/h
Hourly consumption at max 9.50 kg/h
Runtime at min 65.00 h
Runtime at max 10.00 h
Heatable volume 995/35
Diameter of smoke outlet pipe 10 cm
Weight 350 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 130 ºC
Massive smoke capacity 12,7 g/s
Boiler water capacity 80 l

 

Compact Technical designs