Compact Easy Clean

These pellet boilers of the Compact range are fitted as standard with an ash compaction and evacuation system with intervals up to 3 months. Equipped with a handy trolley to make it easier to remove and move the ash, as well as an automatic turbulator and brazier cleaning system with a rotating grid or a compressed-air system. They are completed with a touch-screen panel for an even easier and intuitive control over the system.

CLEANING REDUCED BY -75%

LARGE PELLET TANK PROVIDED (C45: 150 l, C35: 146 l, C18/C24: 100 l)

Diagram of details

New programmable electronics that manages the boiler functions (including chimney sweep and summer/winter functions).
Fully automatic ash extraction system.
Automatic brazier cleaning system with a rotating grid (C45) or a compressed-air system (C18, C24, C35).
Ash extraction system and fully automatic turbolator cleaning.

Technical data

Fuel type pellet
Class compliant with EN303-5 5
Energy Labelling A +
Nominal thermal power to firebox 18.00 kW
Max nominal output power 16.80 kW
Minimum output power 4.60 kW
Thermal power with fluid 16.80 kW
Nominal performance 93.70%
Hopper capability 100.00 l
Hourly consumption at min 1.10 kg/h
Hourly consumption at max 3.70 kg/h
Runtime at min 59.00 h
Runtime at max 18.00 h
Heatable volume 413 m³ (*)
Diameter of smoke outlet pipe 10 cm
Weight 220 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 110 ºC
Massive smoke capacity 10,7 g/s
Boiler water capacity 25 l

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Compact Easy Clean Technical designs
Fuel type pellet
Class compliant with EN303-5 5
Energy Labelling A +
Nominal thermal power to firebox 24.50 kW
Max nominal output power 22.10 kW
Minimum output power 3.80 kW
Thermal power with fluid 22.10 kW
Nominal performance 90.20%
Hopper capability 100.00 l
Hourly consumption at min 1.00 kg/h
Hourly consumption at max 4.80 kg/h
Runtime at min 68.00 h
Runtime at max 15.00 h
Heatable volume 543 m³ (*)
Diameter of smoke outlet pipe 10 cm
Weight 220 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 150 ºC
Massive smoke capacity 17,5 g/s
Boiler water capacity 25 l

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Compact Easy Clean Technical designs
Fuel type pellet
Class compliant with EN303-5 5
Energy Labelling A +
Nominal thermal power to firebox 34.50 kW
Max nominal output power 32.00 kW
Minimum output power 8.10 kW
Thermal power with fluid 32.00 kW
Nominal performance 92.80%
Hopper capability 146.00 l
Hourly consumption at min 1.30 kg/h
Hourly consumption at max 6.70 kg/h
Runtime at min 80.00 h
Runtime at max 16.00 h
Heatable volume 786 m³ (*)
Diameter of smoke outlet pipe 10 cm
Weight 320 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 140 ºC
Massive smoke capacity 21,5 g/s
Boiler water capacity 30 l

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Compact Easy Clean Technical designs
Fuel type pellet
Class compliant with EN303-5 5
Energy Labelling A +
Nominal thermal power to firebox 43.50 kW
Max nominal output power 40.30 kW
Minimum output power 11.70 kW
Thermal power with fluid 40.30 kW
Nominal performance 92.60%
Hopper capability 150.00 l
Hourly consumption at min 2.60 kg/h
Hourly consumption at max 9.00 kg/h
Runtime at min 38.00 h
Runtime at max 11.00 h
Heatable volume 990 m³ (*)
Diameter of smoke outlet pipe 10 cm
Weight 370 kg
Suggested draughtsystem 10-0.10 Pa-mbar
Smoke temperature 140 ºC
Massive smoke capacity 24,3 g/s
Boiler water capacity 50 l

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Compact Easy Clean Technical designs