Selecta

Compact pellet boiler for confined spaces (under the staircase, storage room, small utility compartments, etc.) with high performance levels and extensive operating control. The hydraulic part can be complemented with different kits depending on the system’s requirements. Wide range of pellet loading and storage systems. You can check the temperature of the puffer tank and/or domestic hot water through the boiler’s panel.

Compatible storage and loading systems

Diagram of details

Programmable electronics that manages the boiler functions (including chimney sweep and summer/winter functions).
Sealed combustion chamber.
High-performance ceramic spark plug for quick and reliable ignition.
Large ash tray for a weekly clean.
SELECTA 15-25:
Filling tank provided with a capacity of approximately 100 litres (about 70 kg).
Cast iron grate unit for long-lasting durability.
The hydraulic part can be completed with 2 different kits depending on the system’s needs.
Combustion air that can be ducted from outside for maximum efficiency of the system, ideal for homes with low energy consumption levels (Selecta 15/25).

Technical data

Model Selecta 15 S1
Energy efficiency class A+
Class compliant with EN303-5 5
Fuel type pellet
Nominal thermal power to firebox 13.50 kW
Max nominal output power 15.00 kW
Minimum output power 13.50 kW
Hopper capability 46.00 l
Runtime at max 23.00 h
Diameter of smoke outlet pipe 10 cm
Weight 170 kg
Smoke temperature 113 ºC
Massive smoke capacity 10.40 g/s
Selecta Technical designs
Model SELECTA 20 S1
Energy efficiency class A+
Class compliant with EN303-5 5
Fuel type pellet
Nominal thermal power to firebox 19.90 kW
Max nominal output power 18.00 kW
Minimum output power 4.70 kW
Nominal performance - max 90.50%
Nominal performance - min 88.80%
Hopper capability 72.00 l
Hourly consumption at min 1.00 kg/h
Hourly consumption at max 4.10 kg/h
Runtime at min 47.00 h
Runtime at max 12.00 h
Heatable volume 442/35 m³ (*)
Diameter of smoke outlet pipe 100 cm
Weight 256 kg
Suggested draughtsystem 0.10 Pa-mbar
Smoke temperature 97 ºC
Massive smoke capacity 10.90 g/s

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Selecta Technical designs
Model Selecta 25 ACS S1
Energy efficiency class A+
Class compliant with EN303-5 5
Fuel type pellet
Nominal thermal power to firebox 22.60 kW
Max nominal output power 25.00 kW
Minimum output power 4.85 kW
Nominal performance - max 90.04%
Hopper capability 46.00 l
Runtime at max 18.40 h
Diameter of smoke outlet pipe 10 cm
Weight 170 kg
Smoke temperature 146 ºC
Massive smoke capacity 13.95 g/s
DHW flow rate 12.50 l/min
Selecta Technical designs
Model Selecta 25 S1
Energy efficiency class A+
Class compliant with EN303-5 5
Fuel type pellet
Nominal thermal power to firebox 22.60 kW
Max nominal output power 25.00 kW
Minimum output power 4.85 kW
Nominal performance - max 90.04%
Hopper capability 46.00 l
Runtime at max 18.40 h
Diameter of smoke outlet pipe 10 cm
Weight 170 kg
Smoke temperature 146 ºC
Massive smoke capacity 13.95 g/s
DHW flow rate 12.50 l/min
Selecta Technical designs
Model SELECTA 30 ACS S1
Energy efficiency class A+
Class compliant with EN303-5 5
Fuel type pellet
Nominal thermal power to firebox 30.20 kW
Max nominal output power 27.70 kW
Minimum output power 7.10 kW
Nominal performance - max 93.20%
Nominal performance - min 92.40%
Hopper capability 100.00 l
Hourly consumption at min 1.60 kg/h
Hourly consumption at max 6.30 kg/h
Runtime at min 41.00 h
Runtime at max 10.00 h
Heatable volume 681/35 m³ (*)
Diameter of smoke outlet pipe 100 cm
Weight 290 kg
Suggested draughtsystem 0.10 Pa-mbar
Smoke temperature 89 ºC
Massive smoke capacity 16.20 g/s

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Selecta Technical designs
Model SELECTA 30 S1
Energy efficiency class A+
Class compliant with EN303-5 5
Fuel type pellet
Nominal thermal power to firebox 30.20 kW
Max nominal output power 27.70 kW
Minimum output power 7.10 kW
Nominal performance - max 93.20%
Nominal performance - min 92.40%
Hopper capability 100.00 l
Hourly consumption at min 1.60 kg/h
Hourly consumption at max 6.30 kg/h
Runtime at min 41.00 h
Runtime at max 10.00 h
Heatable volume 681/35 m³ (*)
Diameter of smoke outlet pipe 100 cm
Weight 290 kg
Suggested draughtsystem 0.10 Pa-mbar
Smoke temperature 89 ºC
Massive smoke capacity 16.20 g/s

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Selecta Technical designs
Model SELECTA 35 ACS S1
Energy efficiency class A+
Class compliant with EN303-5 5
Fuel type pellet
Nominal thermal power to firebox 34.20 kW
Max nominal output power 32.00 kW
Minimum output power 7.10 kW
Nominal performance - max 93.60%
Nominal performance - min 92.40%
Hopper capability 100.00 l
Hourly consumption at min 1.60 kg/h
Hourly consumption at max 7.20 kg/h
Runtime at min 41.00 h
Runtime at max 9.00 h
Heatable volume 786/35 m³ (*)
Diameter of smoke outlet pipe 100 cm
Weight 290 kg
Suggested draughtsystem 0.10 Pa-mbar
Smoke temperature 80 ºC
Massive smoke capacity 18.80 g/s

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Selecta Technical designs
Model SELECTA 35 S1
Energy efficiency class A+
Class compliant with EN303-5 5
Fuel type pellet
Nominal thermal power to firebox 34.20 kW
Max nominal output power 32.00 kW
Minimum output power 7.10 kW
Nominal performance - max 93.60%
Nominal performance - min 92.40%
Hopper capability 100.00 l
Hourly consumption at min 1.60 kg/h
Hourly consumption at max 7.20 kg/h
Runtime at min 41.00 h
Runtime at max 9.00 h
Heatable volume 786/35 m³ (*)
Diameter of smoke outlet pipe 100 cm
Weight 290 kg
Suggested draughtsystem 0.10 Pa-mbar
Smoke temperature 80 ºC
Massive smoke capacity 18.80 g/s

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m3

Selecta Technical designs

Download

Selecta 15 S1
SELECTA 20 S1
Selecta 25 S1
Selecta 25 ACS S1
SELECTA 30 ACS S1
SELECTA 30 S1
SELECTA 35 ACS S1
SELECTA 35 S1